BTS410D2 |
RFQ for BTS410D2 |
![]() |
| Product | Manufacturers | Pack | D/C |
| BTS410D2 | - | 01+ | 580 |
Typical Application |
Features |
| · mC compatible power switch with diagnostic feedback for 12 V and 24 V DC grounded loads· All types of resistive, inductive and capacitve loads· Replaces electromechanical relays, fuses and discrete circuits | · Overload protection· Current limitation· Short circuit protection· Thermal shutdown· Overvoltage protection (including load dump)· Fast demagnetization of inductive loads· Reverse battery protection1)· Undervoltage and overvoltage shutdown with auto-restart and hysteresis· CMOS diagnostic output· Open load detection in ON-state· CMOS compatible input· Loss of ground and loss of Vbb protection· Electrostatic discharge (ESD) protection |
| Parameter |
Symbol |
Values |
Unit | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Supply voltage (overvoltage protection see page 3) | Vbb |
43 |
V | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Load dump protection2) VLoadDump = UA + Vs, UA = 13.5 V RI3)= 2 , RL= 5.3 , td= 200 ms, IN= low or high |
VLoad dump4) |
100 |
V | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Load current (Short circuit current, see page 4) | IL |
self-limited |
A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Operating temperature range Storage temperature range |
Tj Tstg |
-40 ...+150 |
°C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Power dissipation (DC), TC 25 °C | Ptot |
50 |
W | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Inductive load switch-off energy dissipation, single pulse Vbb =12V, Tj,start =150°C, TC =150°C const. &nb SupplierPost a Buying LeadPDF / DatasheetRelated PDFRelated Models
|